The measurement module (A) measures the drilled hole. The measurement module is cast in a protective urethane case. The module features multiple motion detectors, a transmitter, internal memory and a wirelessly-charged battery. To activate the module, place it in the charging station.
The measurement module is installed inside the hollow adapter (B) between the drill bit (C) and rod. The measurement module is protected by two springs when it is installed in the adapter.
The measurement module uploads data to the cabin computer when it is in the vicinity of the transceiver. The measurement data is deleted once it has been transferred to the computer. If the transfer is unsuccessful, the data will remain on the module until it has been transferred to the computer. The data in the measurement module's memory will not be lost even if the battery is drained in the middle of the measurement.
The adapter must be attached to the drill bit in the correct position or it may break.